AMVC96. Two-Stage, Variable-Speed. Heating Input: 40, ,000 BTU/h. Contents

Please download to get full document.

View again

of 8
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Information Report
Category:

Devices & Hardware

Published:

Views: 12 | Pages: 8

Extension: PDF | Download: 0

Share
Related documents
Description
Two-Stage, Variable-Speed EM Gas Furnace Up to 96% FUE Heating Input: 0,000 0,000 TU/h ontents Nomenclature... ccessories... Product Specifications... imensions... irflow Specifications... Wiring iagram...8
Transcript
Two-Stage, Variable-Speed EM Gas Furnace Up to 96% FUE Heating Input: 0,000 0,000 TU/h ontents Nomenclature... ccessories... Product Specifications... imensions... irflow Specifications... Wiring iagram...8 Standard Features omfortnet ommunicating System compatible Heavy-duty stainless-steel tubular heat exchanger Stainless-steel secondary heat exchanger Two-stage gas valve provides quiet, economical heating urable Silicon Nitride igniter Quiet two-speed induced draft blower Utilizes omfortnet communicating, two-stage or single-stage thermostats Self-diagnostic control board with constant memory fault code history output to a dual 7-segment display olor-coded low-voltage terminals with provisions for electronic air cleaner and humidifier Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand Multiple continuous fan speed options offer quiet air circulation uto-omfort and enhanced dehumidification modes available ll models comply with alifornia 0 ng/j Low x emissions standard abinet Features esigned for multi-position installation: upflow, horizontal left or right ertified for direct vent (-pipe) or non-direct vent (-pipe) Easy-to-install top venting with optional side venting onvenient left or right connection for gas and electrical service abinet air leakage (QLeak) % Heavy-gauge steel cabinet with durable finish Fully insulated heat exchanger and blower section irtight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications ENER STR and the ENER STR mark are registered trademarks owned by the U.S. Environmental Protection gency. ENER STR products are third-party certified by an EP-recognized ertification ody. Products that earn the ENER STR prevent greenhouse gas emissions by meeting strict energy efficiency guidelines set by the U.S. Environmental Protection gency. * omplete warranty details available from your local dealer or at To receive the Lifetime Heat Exchanger Limited Warranty, the Lifetime Unit Replacement Limited Warranty (in both cases good for as long as you own your home), and the 0-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in alifornia or Québec. SS- / mana is a trademark of Maytag orporation or its related companies and used under license to Goodman ompany, L.P., Houston, Texas. Supersedes 8/ Nomenclature M V N,6 7,8,9 0 rand Minor Revision - mana rand - Initial Release - st Revision onfiguration M - Upflow/Horizontal Major Revision - ownflow/horizontal - Initial Release - st Revision Motor V - Variable Speed EM / omfortnet x E - Multi- Speed EM S - Single Speed N - Low Nox (0ng/J) Gas Valve M - Modulating S - Single Stage abinet Width - Two Stage H - onvertible Single Phase - - - 7½ - ½ FUE 9-9% FUE 97-97% FUE Maximum 96-96% FUE MTU/h ,000 TU/h 00-00,000 TU/h ,000 TU/h 0-0,000 TU/h ,000 TU/h ccessories Model escription 00N 060N 080N 080N 00N 0N TK0 omfortnet-ompatible ontrol VENT- oncentric Vent Kit ( ) VENT- oncentric Vent Kit ( ) FS7 ownflow Sub-ase 7. FS ownflow Sub-ase FS ownflow Sub-ase RF000 rain Kit -Horizontal Left Vertical Flue EFR0 External Filter Rack with 6 x Permanent Filter K00000S Flush Mount Vent Kit - or 070K0000S Flush Mount Vent Kit - FE8-60 Fossil Fuel (ual Fuel) Kit HSFK High-ltitude Natural Gas Kit HSFK- HSFK- HSFK- HSFK- HSFK- HSFK- HSFK High-ltitude LP Gas Kit HSFK- HSFK- HSFK- HSFK- HSFK- HSFK- LPLP0 Low LP Gas Pressure Switch LPM-08 LP onversion Kits SS- Product Specifications 00N 060N 080N 080N 00N 0N Heating ata High Fire Input¹ 0,000 60,000 80,000 80,000 00,000 0,000 High Fire Output¹ 8,00 7,600 76,800 76,800 96,000,00 Low-Fire Steady-State Input¹ 8,000,000 6,000 6,000 70,000 8,000 Low-Fire Steady-State Output¹ 6,880 0,0,760,760 67,00 80,60 FUE² Temperature Range Vent iameter³ - - - - - - No. of urners 6 irculator lower 0. ESP Size ( x W) 0 x 8 x 8 x 8 x 0 x 0 x 07 RPM ½ ½ ½ ¾ Speed VS EM VS EM VS EM VS EM VS EM VS EM Electrical ata Min. ircuit mpacity⁴ Max. Overcurrent evice (amps)⁵ 0 0 Shipping Weight (lbs) ¹ Natural Gas TU/h ² OE FUE based upon Isolated ombustion System (IS) ³ Installer must supply one or two PV pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either or in diameter, depending upon furnace input, number of elbows, length of run and installation ( or pipes). The optional ombustion ir Pipe is dependent on installation/code requirements and must be or diameter PV. ⁴ Minimum ircuit mpacity = (. x irculator lower mps) + I lower amps. Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ⁵ Maximum Overcurrent Protection evice refers to maximum recommended fuse or circuit breaker size. May use fuses or HR-type circuit breakers of the same size as noted. Notes ll furnaces are manufactured for use on V, 60 Hz, single-phase electrical supply. Gas Service onnection ½ FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical ode and/or all existing local codes. For bottom return: Failure to unfold flanges may reduce airflow by up to 8%. This could result in performance and noise issues. For servicing or cleaning, a front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. SS- imensions ir ischarge ir ischarge 8¾ ir Intake Pipe Left-Side rain Trap Exterior Holes 6½ ¾ ⅝ enter imple For lternate ir Intake Pipe O Hole High-Voltage Electrical Outlet Standard Gas Supply Location im ischarge ⅞ ¾ ¾ Vent/ Flue Pipe PV Right-Side rain Trap Exterior Holes High-Voltage Electrical Outlet lternate Gas Supply 6½ 9½ lternate Vent/ Flue Location ¾ ½ ½ Side ut-out 9¼ 9⅝ ⅞ ⅞ 6½ ⅛ 9⅝ 9¼ Side ut-out ⅜ LEFT SIE VIEW Low-voltage Electrical Outlet ⅞ ⅜ ½ ondensate rain Trap Exterior onnection (Right or Left Side) ¾ PV FRONT VIEW Folded Flanges E Unfolded Flanges ⅞ Low-Voltage Electrical Outlet ⅞ ⅜ ½ RIGHT SIE VIEW Folded Flanges ½ Unfolded Flanges Model E 00N 7½ 6 ⅞ ⅛ ⅝ 060N 7½ 6 ⅞ ⅛ ⅝ 080N 7½ 6 ⅞ ⅛ ⅝ 080N 9½ 7⅜ 6 7½ 00N 9½ 7⅜ 6 7½ 0N ½ 0⅞ 9⅜ 0⅞ Minimum learances to ombustible Materials Position Sides Rear Front ottom Flue Top Upflow 0 0 0 Horizontal 6 0 0 6 = If placed on combustible floor, the floor MUST be wood ONLY. SS- irflow ata 00N ooling Speed -.8 w.c. ESP) 00N Heating -. w.c. ESP; Range: 0-0 F) Minus 0% 6 6 Minus 0% Minus % 66 8 Minus % Normal 96 0 Normal Plus % 66 Plus % Plus 0% 66 Plus 0% Minus 0% 76 7 Minus 0% Minus % 76 0 Minus % Normal Normal Plus % 86 Plus % 9 80 Plus 0% Plus 0% Minus 0% Minus 0% Minus % 9 6 Minus % Normal Normal Plus %,0 709 Plus % 89 9 Plus 0%,07 7 Plus 0% Minus 0%,07 7 Minus 0% 80 Minus %, 76 Minus % 86 9 Normal,9 80 Normal Plus %, 8 Plus % 97 6 Plus 0%, 88 Plus 0% N ooling Speed -.8 w.c. ESP) 060N Heating Speed -. w.c. ESP; Range: 0-0 F) Minus 0% 9 8 Minus 0% n/a Minus % Minus % 90 6 n/a Normal Normal n/a Plus % 69 8 Plus %, n/a Plus 0% 69 8 Plus 0%,08 7 n/a Minus 0% 7 0 Minus 0% n/a Minus % Minus %, n/a Normal 87 7 Normal, Plus % 88 8 Plus %, Plus 0% Plus 0%,6 8 6 Minus 0% Minus 0%,0 77 n/a Minus % Minus %, Normal, Normal, Plus %,07 7 Plus %,6 88 Plus 0%, Plus 0%,7 889 Minus 0%,09 79 Minus 0%, 79 7 Minus %, 770 Minus %,97 87 Normal, 80 Normal,60 88 Plus %,7 8 Plus %, 9 0 Plus 0%, 89 Plus 0%, Notes ll furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 00 per ton when cooling is desirable. INSTLLTION IS TO E JUSTE TO OTIN TEMPERTURE RISE WITHIN THE RNGE SPEIFIE ON THE RTING PLTE. Minimum Filter Sizes 00N 060N 080N 080N 00N 0N Filter Size (in²) (Qty) () 6 x (side or bottom) () 0 x (bottom) or () 6 x (side) Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. SS- irflow ata (cont.) 080N ooling Speed -.8 w.c. ESP) Minus 0% N Heating Speed -. w.c. ESP; Range: - 6 F) Normal 69 0 Normal,0 8 9 Minus 0%, n/a Minus % 98 8 Minus %, 8 6 Plus % 660 Plus %, Plus 0% 69 Plus 0%, 9 Minus 0% 7 86 Minus 0%, Minus % 766 Minus %, Normal Normal,6 9 Plus % Plus %,8 969 Plus 0% Plus 0%,8,0 9 Minus 0% 9 6 Minus 0%, Minus % Minus %,0 98 Normal,0 70 Normal,89,0 Plus %,07 70 Plus %,8,08 9 Plus 0%, 776 Plus 0%,8,6 7 Minus 0%,07 77 Minus 0%, Minus %, Minus %,6,00 Normal,0 89 Normal,96,06 Plus %,9 860 Plus %,66,6 9 Plus 0%, 90 Plus 0%,6, N ooling Speed -.8 w.c. ESP) Minus 0% N Heating Speed -. w.c. ESP; Range: - F) Normal 789 Normal,0 867 n/a Minus 0%, n/a Minus % Minus %, 8 n/a Plus % 88 9 Plus %,6 90 n/a Plus 0% Plus 0%, 9 Minus 0% Minus 0%,8 8 n/a Minus % Minus %,0 89 n/a Normal Normal,6 99 Plus %,0 69 Plus %,8 986 Plus 0%,06 76 Plus 0%,8,0 9 Minus 0%,06 7 Minus 0%,0 9 n/a Minus %, 7 Minus %,0 96 Normal,8 79 Normal,89,06 Plus %, 8 Plus %,8,067 9 Plus 0%, Plus 0%,8,8 7 Minus 0%,8 8 Minus 0%,6 969 n/a Minus %, Minus %,6,0 Normal,7 9 Normal,96,077 Plus %, 99 Plus %,66, 9 Plus 0%,,00 Plus 0%,6,8 6 Notes ll furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 00 per ton when cooling is desirable. INSTLLTION IS TO E JUSTE TO OTIN TEMPERTURE RISE WITHIN THE RNGE SPEIFIE ON THE RTING PLTE. 6 SS- irflow ata (cont.) 00N ooling Speed -.8 w.c. ESP) Minus 0% N Heating Speed -. w.c. ESP; Range: - 6 F) Normal 80 6 Normal,88,6 9 Minus 0%,66,0 Minus % Minus %,77,9 Plus % 86 9 Plus %,909,9 7 Plus 0% Plus 0%,000,8 Minus 0%, Minus 0%,68,6 Minus %,076 7 Minus %,777,7 0 Normal, 78 Normal,870,9 8 Plus %,90 8 Plus %,96,7 Plus 0%,6 86 Plus 0%,07, Minus 0%,8 88 Minus 0%,79,8 Minus %,9 9 Minus %,8,0 9 Normal,6 98 Normal,90,6 7 Plus %,7,0 Plus %,006,8 Plus 0%,60,080 Plus 0%,0,8 Minus 0%,6, Minus 0%,76, 0 Minus %,69,96 Minus %,89,90 8 Normal,76,9 Normal,97,8 Plus %,8, Plus %,0,6 Plus 0%,90,8 Plus 0%,,9 0N ooling Speed -.8 w.c. ESP) Minus 0% N Heating Speed -. w.c. ESP; Range: - 6 F) Normal Normal,89,9 6 Minus 0%,70,96 6 Minus % 8 0 Minus %,796,6 9 Plus % 90 7 Plus %,986,9 Plus 0% 9 60 Plus 0%,080,6 Minus 0%,0 78 Minus 0%,76,6 6 Minus %,0 789 Minus %,8,9 8 Normal,60 8 Normal,90,6 Plus %,8 87 Plus %,07,0 Plus 0%,76 9 Plus 0%,,98 0 Minus 0%,0 98 Minus 0%,77, 60 Minus %,9 969 Minus %,870, 7 Normal,67,00 Normal,968,90 Plus %,0,07 Plus %,066,60 Plus 0%,6, Plus 0%,6,9 9 Minus 0%,79,0 Minus 0%,8,96 8 Minus %,8, Minus %,97,68 Normal,90,78 Normal,08,0 Plus %,006, Plus %,9, 0 Plus 0%,0,06 Plus 0%,,8 8 Notes ll furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 00 per ton when cooling is desirable. INSTLLTION IS TO E JUSTE TO OTIN TEMPERTURE RISE WITHIN THE RNGE SPEIFIE ON THE RTING PLTE. SS- 7 EHUM Wiring iagram GR GN YL R IRUIT ONNET TWO STGE GS VLVE (ITEROGERS) YL R GN EM MTR HRNESS HOT SURFE IGNITER L / V HUM- OUT E 0 7 FUSE LOW FIRE PRESSUR E SWITH UTO RESET UXILIRY LIMIT ONTROL HUM- IN 8 R LINE 9 6 R HUM R OOL F TRIM % OOL PRFL HET F EHUM ENLE TRIM ENLE ONT FN HET OFF LY SEE TE MNUL RESET ROLLOUT LIMIT ONTROLS (SINGLE ONTROL ON 0 ktu) UTO RESET PRIMRY LIMIT ONTROL PM LOWER OMPRTMENT HI URNER OMPRTMENT L IRULT LOWER I LOWER TWO-STGE PRESSURE SWITH SSEMLY NEUTRL FS T-STT G L W W Y IP SWITHES Y IRUIT ONNET IRUIT MOT ONNET TWO-STGE INTEGRTE ONTROL MOULE IGSTI LE'S O V THERMOSTT ONNETIONS GR FRONT OVER PRESSURE SWITH GN GN YL INUE RFT LOWER EHUM 0 V R L TRNSFMER INUT OIL (ON SOME MOELS) HIGH FIRE PRESSURE SWITH V V JUNTION OX YL FLME SENS L GN R HSSIS GROUN LOWER OMPRTMENT O SWITH (OPEN EN O OPEN) WRNING: ISONNET POWER EFE SERVIING. WIRING TO UNIT MUST E PROPERLY POLRIZE N GROUNE. INTEGRTE ONTROL MOULE V THERMOSTT ONNETIONS TO V/ Ø /60 HZ POWER SUPPLY WITH OVERURRENT PROTETION EVIE R Y W W Y G O TO GN V/ Ø /60 HZ POWER SUPPLY WITH OVERURRENT PROTETION EVIE L N ISONNET O SWITH JUNTION OX INUT OIL (ON SOME MOELS) LINE PS () TO MIRO HIGH FIRE PRESS. SWTIH SEE TE 6 HUMIIFIER HUM-OUT HUMIIFIER NEUTRL HUM E NEUTRL ELETRONI IR LENER IN HI NEUTRL I LWR NEUTRL IGN IN LO HOT SURFE IGNITER FS FLME SENS LINE V NEUTRL 0 V FUSE TH () TRNSFMER V UTO RESET PRIMRY UTO RESET UXILIRY LIMIT LIMIT ONTROL TO +V ONTROLS HLO (0) PSO (7) PS () MNUL RESET ROLLOUT LIMIT ONTROLS HLI () MVL () PM MV (8) HI MVH () GN () TR () TO GN () R + V () RX () I IR TO IRULT MIRO TX () LWR UX INTEGRTE ONTROL MOULE L WRNING:ISONNET POWER EFE SERVIING. WIRING TO UNIT MUST E PROPERLY POLRIZE N GROUNE. GN N I IR IRULT LWR GN HUM-IN GN FRONT OVER PRESSURE SWITH GN ISONNET NEUTRL LOW FIRE PRESS. SWITH GS VLVE INTEGRTE ONTROL MOULE High Voltage: isconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Warning Wiring is subject to change. lways refer to the wiring diagram on the unit for the most up-to-date wiring. TES:. SET HET NTIIPT ON ROOM THERMOSTT T 0.7 MPS.. MNUFTURER'S SPEIFIE REPLEMENT PRTS MUST E USE EN SERVIING.. IF NY OF THE IGINL WIRE S SUPPLIE WITH THE FURNE MUST E REPLE, IT MUST E REPLE WITH WIRING MTERIL HVING TEMPERTURE RTING OF T LEST 0 $. USE OPPER ONUTS ONLY.. UNIT MUST E PERMNENTLY GROUNE N ONFM TO N.E.. N LOL OES.. TO RELL THE LST 6 FULTS, MOST REENT TO LEST REENT, EPRESS SWITH F ME THN SEONS ILE IN STNY ( THERMOSTT INTS) 6. HUMIIFIER INSTLLTION OPTIONS: USE HUM TERMINL TO RUN HUMIIFIER URING HET LL (OMMUNITING LEGY MOES). USE HUM-IN N HUM-OUT TERMINLS TO RUN HUMIIFIER URING HET LL ( OMMUNITING MOE LEGY MOE) INEPENENTLY FROM HET LL (OMMUNITING MOE ONLY - SETUP IS ONE WITHIN OMMUNITING THERMOSTT) OL OES: PINK R ROWN ITE L LUE GRY RE YL YELLOW NGE RPLE GN GREEN LK LOW VOLTGE (V) LOW VOLTGE FIEL HI VOLTGE (V) HI VOLTGE FIEL JUNTION TERMINL INTERNL TO INTEGRTE ONTROL PLUG ONNETION EQUIPMENT GN FIEL GN FIEL SPLIE SWITH (TEMP.) IGNITER SWITH (PRESS.) OVERURRENT PROT. EVIE 00F0006- mana is a registered trademark of Maytag orporation or its related companies and used under license to Goodman ompany, L.P. ll rights reserved. Our continuing commitment to quality products may mean a change in specifications without notice. 0 Goodman ompany, L.P. Houston, Texas 8 SS-
Recommended
View more...
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks