9702_s13_ms_32

Please download to get full document.

View again

of 4
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Information Report
Category:

Creative Writing

Published:

Views: 7 | Pages: 4

Extension: PDF | Download: 0

Share
Related documents
Description
CAMBRIDGE INTERNATIONAL EXAMINATIONS GCE Advanced Subsidiary Level and GCE Advanced Level MARK SCHEME for the May/June 2013 series 9702 PHYSICS 9702/32 Paper 3…
Transcript
CAMBRIDGE INTERNATIONAL EXAMINATIONS GCE Advanced Subsidiary Level and GCE Advanced Level MARK SCHEME for the May/June 2013 series 9702 PHYSICS 9702/32 Paper 3 (Advanced Practical Skills 2), maximum raw mark 40 This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the details of the discussions that took place at an Examiners’ meeting before marking began, which would have considered the acceptability of alternative answers. Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for Teachers. Cambridge will not enter into discussions about these mark schemes. Cambridge is publishing the mark schemes for the May/June 2013 series for most IGCSE, GCE Advanced Level and Advanced Subsidiary Level components and some Ordinary Level components. Page 2 Mark Scheme Syllabus Paper GCE AS/A LEVEL – May/June 2013 9702 32 1 (b) (ii) Value of t in the range 10.0 s ≤ t ≤ 20.0 s. [1] Evidence of repeat measurements of t. [1] (c) Six sets of readings of S and t scores 5 marks, five sets scores 4 marks etc. [5] If trend wrong or no S or t column –1. Major help from Supervisor –2 (setting up circuit). Minor help from Supervisor –1. Range: [1] Values of S must include 22 (kΩ) or 10 (kΩ) and 1.2 (kΩ) or 1.0 (kΩ). Column headings: [1] Each column heading must contain a quantity and a unit. The presentation of quantity and unit must conform to accepted scientific convention e.g. 1/t / s–1 1/S / kΩ –1 1/S (kΩ –1) t / s t (s). ( 1/t(s) 1/S 1/kΩ 1/S (kΩ) –1 are not allowed.) Consistency: [1] All values of raw t must be given to the same precision (either 0.1 s or 0.01 s). Significant figures: [1] Significant figures for every row of values of 1/S must be the same as or one greater than the s.f. in S as recorded in table. Calculation: [1] Values of 1/t calculated correctly. (d) (i) Axes: [1] Sensible scales must be used, no awkward scales (e.g. 3:10). Scales must be chosen so that the plotted points occupy at least half the graph grid in both x and y directions. Scales must be labelled with the quantity that is being plotted. Scale markings should be no more than three large squares apart. Plotting of points: [1] All observations in the table must be plotted. Points must be plotted to an accuracy of half a small square. Diameter of points must be ≤ half a small square (no “blobs”). Quality: [1] All points in the table must be plotted (at least 5) for this mark to be awarded. Judge by the scatter of all the points about the straight line. Points must be less than 0.05 kΩ ─1 from a straight line on the 1/S axis. (ii) Line of best fit: [1] Judge by balance of all points on the grid about the candidate’s line (at least 5 points). There must be an even distribution of points either side of the line along the full length. Allow one anomalous point only if clearly indicated (i.e. circled or labelled) by the candidate. Line must not be kinked or thicker than half a small square. © Cambridge International Examinations 2013 Page 3 Mark Scheme Syllabus Paper GCE AS/A LEVEL – May/June 2013 9702 32 (iii) Gradient: [1] The hypotenuse of the triangle must be at least half the length of the drawn line. Both read-offs must be accurate to half a small square in both the x and y directions. The method of calculation must be correct. y-intercept: [1] Either: Correct read-off from a point on the line substituted into y = mx + c. Read-off must be accurate to half a small square in both x and y directions. Or: Intercept read off directly from the graph. (e) Value of a = candidate’s gradient. Value of b = candidate’s intercept / candidate’s gradient = candidate’s intercept / a [1] Unit for a correct and consistent with value e.g. kΩ s–1, Ω s–1. [1] [Total: 20] 2 (a) (i) Measurement of d with unit in range 0.5 mm – 2.5 mm. [1] Evidence of repeated readings of d. [1] (ii) Absolute uncertainty in d in the range 0.2 – 0.5 mm. [1] If repeated readings have been taken, then the absolute uncertainty can be half the range (but not zero if values are equal). Correct method of calculation to get percentage uncertainty. (c) (i) Measurement of r1 recorded to nearest 0.1 cm3, and in range 1 to 5 cm3. [1] (ii) Value for n. [1] (iii) Correct calculation of V. [1] (d) Justification of s.f. in V linked to significant figures in (r1 – r2) and in n. [1] (e) (ii) Second value of d. [1] (iii) Second value of n. [1] Quality: V larger for larger d. [1] (f) (i) Two values of k calculated correctly. [1] (ii) Sensible comment relating to the calculated values of k, testing against a criterion specified by the candidate. [1] © Cambridge International Examinations 2013 Page 4 Mark Scheme Syllabus Paper GCE AS/A LEVEL – May/June 2013 9702 32 (g) (i) Limitations 4 max. (ii) Improvements 4 max. Do not credit A two readings not enough (to draw a take many readings and plot a repeat readings/few conclusion) graph/take many readings and readings/take more calculate more k values and readings and compare (calculate) average k/only one reading B1 large uncertainty in d because d is improved method to measure d flexible tube/rigid small e.g. measure OD and wall tube/wire in thickness/image of cross-section tube/micrometer/d is with scale small B2 difficult to measure d with reason use travelling e.g. tube distorts/difficult to insert microscope/measure volume both prongs inside tube/difficult to and calculate d/use a judge when jaws are in line with magnifying glass with scale edges of d C difficult to count bubbles with method to improve control bubbles difficult to reason e.g. use a G-clamp or screw to count/lubrication e.g. plunger moves move plunger/use a narrower unsteadily/plunger sticks/bubbles diameter syringe with reason unexpected/bubbles emerge too (e.g.smaller force needed so quickly better control) D difficult to watch the syringe scale description of method to allow parallax/use and the bubbles at the same time simultaneous measurement assistant/change e.g. use video with playback/use syringe scale/high video to allow slow motion/use speed camera/slow video to see bubbles motion camera/light gates E difficult to keep end of tube at 2 cm method to keep tube at 2 cm stick tube/attach depth depth tube/water in e.g. use of clamp/Blu-Tack/tape tube/comments about Blu-Tack seal [Total: 20] © Cambridge International Examinations 2013
Recommended
9702_s10_ms_32

9702_s10_ms_32

4 pages

9702_s16_ms_32

9702_s16_ms_32

4 pages

9702_s15_ms_32

9702_s15_ms_32

4 pages

9702_s14_ms_32

9702_s14_ms_32

4 pages

9702_s13_qp_32

9702_s13_qp_32

12 pages

9702_s13_ms_53

9702_s13_ms_53

4 pages

9702_s13_ms_43

9702_s13_ms_43

6 pages

9702_s13_ms_41

9702_s13_ms_41

6 pages

9702_s13_ms_52

9702_s13_ms_52

4 pages

9702_s13_ms_31

9702_s13_ms_31

4 pages

9702_s13_ms_51

9702_s13_ms_51

4 pages

9702_s13_ms_33

9702_s13_ms_33

4 pages

9702_s13_ms_34

9702_s13_ms_34

4 pages

9702_s13_ms_42

9702_s13_ms_42

7 pages

9702_s13_ms_32

9702_s13_ms_32

4 pages

View more...
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks