CamIO User Manual. 230 V~/115V~ 8 to 48 V~ In1. In2. Complete integration for web and security. MOBOTIX AG Security-Vision-Systems Made in Germany

Please download to get full document.

View again

of 60
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Information Report
Category:

Biography

Published:

Views: 0 | Pages: 60

Extension: PDF | Download: 0

Share
Related documents
Description
Megapixel 1280 x 960 software zoom 30 Frames/s VGA (640 x 480) 10 fps Mega -22 F to +140 F Weatherproof -30 C to +60 C, IP65 no heating necessary IEEE 802.3af PoE network power even in winter microphone
Transcript
Megapixel 1280 x 960 software zoom 30 Frames/s VGA (640 x 480) 10 fps Mega -22 F to +140 F Weatherproof -30 C to +60 C, IP65 no heating necessary IEEE 802.3af PoE network power even in winter microphone & speaker Audio bi-directional via IP variable framerates Video SIP Client IP Telephony alarm notify, cam remote control Video motion multiple windows precision pixel-based lip-syncronized audio Recording event-ringbuffer 30 cams each 30 fps Live viewing 30 cams at 30 fps all on one screen Backlight safe using CMOS without mechanical iris Vandalism-protected Wall bracket with cable cover for RJ45 wall outlet Robust no moving parts fiber glass housing Lamp Door CamIO User Manual MOBOTIX CamIO Out2 Out V~/115V~ 8 to 48 V~ Complete integration for web and security Current PDF File: Support Manuals MOBOTIX AG Security-Vision-Systems Made in Germany In1 In2 Line-In Speaker 8 8 to 230 V~ (8 to 48 V~) 8 to 230 V~ (8 to 48 V~) RJ45 Microphone with pre-amplifier Speaker Security-Vision-Systems X MOBOTIX MOBOTIX... the new face of IP video.com MOBOTIX CamIO User Manual Caution Only qualified personnel may install and open the CamIO and connect it to the mains power; make sure that the relevant regulations of your country are respected! It is imperative that all electrical wires have been disconnected from the mains power when working on or servicing the CamIO! Please also make sure to adhere to the applicable regulations for this kind of work! MOBOTIX will not assume any responsibility for damages from faulty installations or inappropriate use! Notes Note: MOBOTIX offers inexpensive seminars that include a workshop and practical exercises: Basic Seminar three days, Advanced Seminar two days. For more information, see MOBOTIX CamIO User Manual 1/56 CamIO User Manual 1 INTRODUCTION MOBOTIX CamIO Concept The MOBOTIX CamIO and MOBOTIX Cameras Functional Overview of the CamIO Models Connection Cables between CamIO and MOBOTIX Cameras Important Notes Safety Regulations Cables for the MOBOTIX CamIO Minimum Load at the Signal Outputs Safety Notes for Operating the MOBOTIX CamIO Maximum Cable Lengths Charging the Rechargeable Battery (CamIO-ACplus) Weatherproofness, Temperature Range Cleaning Instructions Additional Information 12 2 MOUNTING Delivered Parts, Components, Dimensions and Connectors Delivered Parts and Components Wall Mount Foot and Housing Dimensions and Drilling Template Connectors and Wiring Information on Connecting the MOBOTIX CamIO Mounting the CamIO Wall Mount and the Control Cable Mounting with an M12 Camera Mounting with an M22 Camera Mounting the CamIO Housing and Installing the Cables Mounting the CamIO Housing on the Wall Power Supply of the CamIO Ethernet Connection of the CamIO Connecting External Components to the CamIO Connecting External Devices, Sensors and Audio Devices Mounting the Camera on the CamIO Connecting the Additional Speaker in the Wall Mount Foot Connecting the Ethernet and the CamIO Control Cables Wiring, Fire Prevention, Lightning and Surge Protection Wiring Fire Prevention Lightning and Surge Protection Accessories, Replacement Parts 40 2/56 MOBOTIX CamIO User Manual 3 OPERATION OF THE CAMIO Activating the CamIO Configuration Sample Functional Overview Terminal Connections of the CamIO Overview of the Configuration Steps Configuring the MOBOTIX Camera Configuring a Softphone 51 4 TECHNICAL SPECIFICATIONS 52 APPENDIX: DECLARATION OF CONFORMITY DRILLING TEMPLATE (SCALE 1:1) Download the latest version of this document as a PDF file from Support Manuals Note Download the latest version of this document as a PDF file from Support Manuals. Information subject to change without notice! Copyright MOBOTIX AG, Kaiserslautern, Germany. All rights reserved. MOBOTIX, MxPEG and MxControlCenter are worldwide trademarks of MOBOTIX AG. Microsoft, Windows and Windows Server are registered trademarks of Microsoft Corporation. Apple, the Apple logo, Mac and Mac OS X are trademarks of Apple Inc. Linux is a trademark of Linus Torvalds. All other marks and names mentioned herein may be trademarks or registered trademarks of the respective owners. MOBOTIX CamIO User Manual 3/56 Notes 4/56 MOBOTIX CamIO User Manual All CamIO models can be used with the MOBOTIX M12 and M22 cameras (IT and Secure models). The CamIO can switch Ohm resistive loads with max. 5 A, (max. 500 W lamps at 230 V or 300 W lamps at 115 V). 1 INTRODUCTION The MOBOTIX CamIO is the expansion box for connecting the MOBOTIX cameras M12 and M22M (IT and Secure models). In the security and home automation fields, the CamIO is the ideal supplement to the MOBOTIX cameras, if you want to switch lamps, doors, control wires, pushbuttons or other external devices, evaluate other sensors than those in the camera or use external audio devices (M12 models only). An external device (e.g. a lamp) connected to the CamIO-AC/ACplus can be powered directly by the CamIO and is switched on or off using the first signal out put of the MOBOTIX camera. The second signal output can be used for potential free switching of another external device (e.g. door opener; max. 230V~ or 48V~/ 68V=, depending on the CamIO model). This signal output can also be used to connect the MOBOTIX camera to the input of an alarm system, for example. You can also attach external sensors to the MOBOTIX camera via the CamIO, e.g. to evaluate remote sensors, such as light barriers, reed switches, external PIR sensors or the output of an alarm system. MOBOTIX CamIO User Manual 5/56 When mounting the MOBOTIX CamIO, the foot of the CamIO wall mount replaces the original foot of an M12 or M22 camera mount. The foot of the CamIO wall mount covers the CamIO and reliably protects it against atmospheric exposure (IP65). In addition, the foot of the CamIO wall mount also contains an additional speaker, which is more powerful than the camera's internal speaker. CamIO models CamIO-PoE: This model is supplied using PoE (IEEE 802.3af), which powers the camera and the CamIO itself. The signal output Out1 can switch one external device (max. 5 A), if max. 48 V~ or 68 V= have been connected to terminals 1 and 2; the signal output Out2 can be used for potential-free switching of another external device (max. 5 A) with max. 48 V~ or 68 V=. The CamIO-PoE also features two signal inputs, one audio input (Line-In) and one MX-CAMIO-POE audio output for directly connecting the supplied additional speaker (max. 2.5 W/8 Ω). PoE Currently, the audio features of the CamIO can only be used with M12 cameras. A future version of the CamIO will support external speakers and microphones also on M22 cameras. CamIO-AC: This model has the same features as the CamIO-PoE, but it can be connected directly to utility power (230 V~/ 115 V~) and can power one external device with up to 230 V~ current (Ohm resistive load, max. 5 A, max. 500 W lamp on 230 V~, max. 300 W on 115 V~). It can also be used for potential-free switching of a second external device (max. 5 A) with up to 230 V~/ 115 V~ at signal output Out2. MX-CAMIO-AC-230 MX-CAMIO-AC V 115 V The CamIO AC and ACplus versions are VDE-certified CamIO-ACplus: In addition to the features of the CamIO-AC, the CamIO-ACPlus has a rechargeable battery, which provides a backup power supply for the M12 models even during power failures (approx. 45 minutes at 20 C/68 F, 20 minutes at -20 C/-4 F). Battery Using the backup power feature of the CamIO- ACplus requires a MOBOTIX M12. M22 cameras do not support this feature yet. MX-CAMIO-ACPLUS-230 MX-CAMIO-ACPLUS-115 6/56 MOBOTIX CamIO User Manual 1.1 MOBOTIX CamIO Concept Simple Installation When designing the MOBOTIX CamIO, special focus was placed on easy installation of the expansion box. The supplied drilling template facilitates mounting the CamIO and connecting the cabling for devices and data connections is easy, secure and weatherproof. To supply power to an external device (terminals 3 and 4), make sure that the CamIO itself is connected to the power supply (terminals 1 and 2). Directly supplying power to and switching of external devices The CamIO-AC and CamIO-ACplus models can directly power one device at signal output Out1 (230 V~/115 V~ at terminals 1 and 2 required), allowing you to switch this device from the MOBOTIX camera (max. 5 A, max. 500 W lamp on 230 V, max. 300 W on 115 V). You can use the second signal output Out2 for potential-free switching of another external device. The CamIO-PoE model has similar possibilities for switching devices, but can only switch loads of up to 48 V~/68 V=. ETHERNET CAMERA ETHERNET P N MOBOTIX CamIO User Manual 7/56 Backup power using the CamIO-ACplus The integrated rechargeable battery of the CamIO-ACplus model can bridge smaller power failures and thus protects the integrity of the video and audio data. At room temperature (20 C/68 F), the CamIO can power a MOBOTIX M12D for about 45 minutes; at -20 C (-4 F), the CamIO still provides 20 minutes of backup power. Providing backup power for an M22M using a CamIO-ACplus is currently not possible. Using external sensors Using the two signal inputs of the CamIO, the MOBOTIX camera can monitor external sensors and apply the different mechanisms available to the camera for storing audio/video and for sending notification messages. Connecting audio devices to M12 Cameras Using the audio terminal of the MOBOTIX CamIO (Audio-Out), you can attach the supplied external speaker in the wall mount foot to the MOBOTIX camera (2.5 W/8 Ω; M12 models only). If you connect an external microphone via an external pre-amplifier to the Line-In terminals of the CamIO, the MOBOTIX camera will also use this input device. It is likewise possible to connect the Line-In terminals of the CamIO to the Line-Out connector of a computer. Weatherproof The weatherproofness of the MOBOTIX CamIO has been tested extensively and has reached IP65 (absolutely dustproof and resistant against water jets). Special attention has been paid to the waterproofness of the power cables, for which special cable seals have been developed. The CamIO-ACplus can provide backup power for a MOBOTIX M12D for about 45 minutes. Using the backup power feature of the CamIO- ACplus requires a MOBOTIX M12. M22 cameras do not support this feature yet. Currently, the audio features of the CamIO can only be used with M12 cameras. A future version of the CamIO will support external speakers and microphones also on M22 cameras. Robust and durable Like all other MOBOTIX products, the CamIO has been designed for a long product life. The housing from PBT-30GF is robust and reliably protects the interior of the CamIO. 8/56 MOBOTIX CamIO User Manual 1.2 The MOBOTIX CamIO and MOBOTIX Cameras Functional Overview of the CamIO Models All CamIO models can be used with MOBOTIX M12 and M22 cameras (IT/Secure models). CamIO-PoE Mx-CAMIO-POE CamIO-AC Mx-CAMIO-AC-230 Mx-CAMIO-AC-115 CamIO-ACplus Mx-CAMIO-ACPLUS-230 Mx-CAMIO-ACPLUS-115 Using the backup power feature of the CamIO- ACplus requires a MOBOTIX M12. M22 cameras do not support this feature yet. Hardware Features Outdoor - weatherproof IP65 IP65 IP65 Power Supply Integrated rechargeable battery PoE V~ / PoE 115 V~ / PoE V~ / PoE 115 V~ / PoE X Concealed cabling X X X Features M12 M22M M12 M22M M12 Currently, the audio Audio Out (speaker/microphone) X - X - X features of the CamIO can only be used with M12 cameras. A future version of the CamIO will support external speakers and microphones also on M22 cameras. Line In (microphone with pre-amp.) Signal outputs Signal inputs Input voltage (terminals 1 and 2) X to 48 V~ 11 to 68 V= X V~ 115 V~ - 2 X V~ 115 V~ Note In order to use all features of the CamIO, make sure that you are activating it in the camera software (Admin Menu Manage Hardware Expansions). Please note that you will need a software version x or higher on the MOBOTIX M22M and a software version x or higher on the MOBOTIX M12. MOBOTIX CamIO User Manual 9/ Connection Cables between CamIO and MOBOTIX Cameras Two cables are required to connect the MOBOTIX camera to the CamIO: Ethernet cable: Establishes the data connection and the power supply to the camera. Control cable: Connects the serial interface (M12) or the USB interface (M22) of the camera in order to provide the signal outputs and inputs of the camera at the CamIO. The different cameras require different control cables, which need to be ordered separately. The control cable required for connecting the CamIO is not part of the standard delivery. Always order a corresponding control cable for your M12 or M22. Control cable for the MOBOTIX M12 MX-CAMIO-OPT-M12 Control cable for the MOBOTIX M22M MX-CAMIO-OPT-M22 10/56 MOBOTIX CamIO User Manual 1.3 Important Notes Safety Regulations Caution Only qualified personnel may install and open the CamIO and connect it to the mains power; make sure that the relevant regulations of your country are respected! It is imperative that all electrical wires have been disconnected from the mains power when working on or servicing the CamIO! Please also make sure to adhere to the applicable regulations for this kind of work! MOBOTIX will not assume any responsibility for damages from faulty installations or inappropriate use! For information on allowed cable diameters and lengths, see chapter 4, Technical Specifications Cables for the MOBOTIX CamIO Only use cables, which have been approved for the pertinent type of installation. Always observe the allowed wire cross-sectional sizes (see table below) and the maximum cable lengths. Connecting the power supply: To provide the power supply to the CamIO, a two-wire cable is required. A ground conductor is not needed. If a power cable with ground conductor is used, this wire must not be connected in the junction box. Instead, connect the ground conductor of any attached device in the junction box. Ground CamIO Lamp Make sure that the fuse for this cable is not stronger than 16 A. Connecting an electrical device: In order to provide power to an external device (Ohm resistive load, max. 5 A, 500 W lamp on 230 V, max. 300 W lamp on 115 V), the CamIO switches two wires (phase conductor and neutral). A ground conductor for grounding the external device needs to come from the junction box. Connecting signal wires and external sensors: Use suitable installation cable for connecting another relay or a signal line (e.g. to an alarm system) or an external sensor. Connecting the Ethernet cable: Make sure that you are using a suitable eight-wire Ethernet installation cable CAT5 (or higher) for connecting the CamIO to the patch panel of a structured wiring system in a building. Make sure that you are completely removing the shielding of the Ethernet cable and that no part of the shielding touches the circuit board. Junction box MOBOTIX CamIO User Manual 11/56 Allowed Cable Dimensions Solid AWG Bottom terminal (terminals 1 to 16) Ethernet terminal (cutting clamps) 0.14 to 2.5 mm to 0.31 mm 2 26 to to 22 Cable diameters should be tailored to the electrical load and must follow the applicable regulations. AWG: American Wire Gauge (for measuring cable diameters) Note The length of the cables for signal wires and external sensors is not restricted. You need to make sure, however, that the minimum voltage at the corresponding terminal is reached (see chapter 4, Technical Specifications). A possible loss of voltage due to the resistance of the wires needs to be considered Minimum Load at the Signal Outputs In order to avoid oxidation of the relay points, you should use minimum loads of 5 V=/100 ma Safety Notes for Operating the MOBOTIX CamIO When installing the wiring inside or outside of buildings, make sure you always adhere to the relevant regulations on wiring, fire prevention and protection against lightning. MOBOTIX recommends having MOBOTIX devices installed only by certified specialists accustomed to installing network devices and having proper respect for the applicable regulations regarding lightning protection and fire prevention as well as the current technology for preventing damages from electrical surges. More information is available at an institution such as the International Electrotechnical Commission (IEC, or at a manufacturer of protection devices against lightning and electrical surges, such as Dehn (www.dehn.de). Wiring When installing the wiring, make sure to follow these guidelines: Outdoors: Installing the camera outdoors requires special precautions and measures regarding the cables as well as lightning and surge protection (see further below in this section). Wire lengths: The cable segments must not exceed the maximum allowed cable lengths in order to ensure proper data transfer (see also section 3.3, Connecting the Camera to the Network and to the Power Supply, in the corresponding camera manual). Avoid induction: When running data cables parallel to existing regular power lines or high-voltage wires, make sure you observe the minimum distances to the power cables. 12/56 MOBOTIX CamIO User Manual Fire Prevention When installing the power lines to the camera, make sure you always adhere to the relevant regulations on wiring and fire prevention at the site of the installation. Lightning and Surge Protection To prevent damage from lightning and power surges, make sure you follow these guidelines: Lightning conductors: In areas exposed to lightning (e.g. on roofs), a distance holder (1 m (3 ft) above and away from the camera) and proper lightning conductors need to be installed in order to prevent lightning strikes into the camera and to ensure that the energy of a lightning strike is properly led to the ground. Surge protection: Make sure you have installed proper protection against electrical surges in order to prevent damage to the camera, the building and the network infrastructure. This includes surge protectors for 19 racks, adding an uninterruptible power supply (UPS) to the MOBOTIX camera, and installing surge arresters or similar for routers, switches, servers, etc Maximum Cable Lengths According to UL regulations, the length of the cable to a MOBOTIX camera must be limited to 140 feet or less running outside of buildings. The installation must comply with articles 725 and 800 of the National Electric Code Charging the Rechargeable Battery (CamIO-ACplus) The CamIO-ACPlus model features a rechargeable battery, which provides backup power supply even during power failures (approx. 45 minutes at 20 C/ 68 F, 20 minutes at -20 C/-4 F). Please note that the full capacity of the rechargeable battery is only available after the CamIO has been attached to mains power for at least 48 hours Weatherproofness, Temperature Range The housing of the MOBOTIX CamIO is weatherproof (IP65, absolutely dustproof, resistant against water jets) and can be used at temperatures from -30 to +60 C (-22 to +140 F) Cleaning Instructions The housing of the MOBOTIX CamIO and the wall mount foot are made of fiber-reinforced PBT-30GF. This material is robust, maintenance-free and can be cleaned using a mild household detergent without solvents or abrasive particles Additional Information For additional information on the MOBOTIX CamIO, see MOBOTIX CamIO User Manual 13/56 Notes 14/56 MOBOTIX CamIO User Manual 2 MOUNTING 2.1 Delivered Parts, Components, Dimensions and Connectors Delivered Parts and Components Allen screws M6x40 (item 6) Washers ø6.4 mm (item 7) Allen wrench 5 mm (item 12) Speaker with audio cables (item 11) NET plug (item 5) Screw caps for wall mount (item 10) The control cable required for connecting the camera to the CamIO is not part of the standard delivery. Always order the corresponding control cable for your M12 or M22. Control cable for the CamIO (not included in delivery; needs to be ordered separately!) Cable seals with 3/5 fingers (item 4) Cover for wall mount foot (item 3) Wood screws 5x80 mm (item 8) Dowels 8 mm (item 9) Item Count Part Name CamIO Wall Mount Foot CamIO Housing Cover for wall mount Cable
Recommended
View more...
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks