ATV630U55N4 variable speed drive ATV kW/7.5HP V - IP21/UL type 1 - PDF

Please download to get full document.

View again

of 13
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Information Report
Category:

Bills

Published:

Views: 4 | Pages: 13

Extension: PDF | Download: 0

Share
Related documents
Description
Characteristics variable speed drive ATV kW/7.5HP V - IP21/UL type 1 Main Range of product Product or component type Product specific application Device short name Variant Product destination
Transcript
Characteristics variable speed drive ATV kW/7.5HP V - IP21/UL type 1 Main Range of product Product or component type Product specific application Device short name Variant Product destination Mounting mode EMC filter Mar 12, 2017 Altivar Process ATV600 Variable speed drive Process and utilities ATV630 Standard version Synchronous motors Asynchronous motors Wall mount IP degree of protection IP21 IEC IP21 IEC Degree of protection Type of cooling Integrated EN/IEC category C2 50 m Integrated EN/IEC category C3 150 m UL type 1 UL 508C Forced convection Supply frequency Hz % Network number of phases 3 phases [Us] rated supply voltage V % Motor power kw Motor power hp Line current Prospective line Isc Apparent power Continuous output current Maximum transient current 5.5 kw normal duty 4 kw heavy duty 7.5 hp normal duty 5 hp heavy duty 10.4 A 380 V normal duty 9.1 A 480 V normal duty 8 A 380 V heavy duty 7.2 A 480 V heavy duty 50 ka 7.6 kva 480 V normal duty 6 kva 480 V heavy duty 12.7 A 4 khz normal duty 9.3 A 4 khz heavy duty 14 A 60 s normal duty 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications Asynchronous motor control profile Synchronous motor control profile Output frequency Nominal switching frequency Switching frequency 14 A 60 s heavy duty Optimized torque mode Variable torque standard Constant torque standard Permanent magnet motor khz 4 khz khz adjustable khz with derating factor Safety function STO (safe torque off) SIL 3 Discrete input logic Communication port protocol Option card 16 preset speeds Modbus serial Ethernet Modbus TCP Communication module Profibus DP V1 slot A Communication module Profinet slot A Communication module DeviceNet slot A Communication module Modbus TCP/EtherNet/IP slot A Communication module CANopen daisy chain RJ45 slot A Communication module CANopen SUB-D 9 slot A Communication module CANopen screw terminals slot A Digital and analog I/O extension module slot A/slot B Output relay extension module slot A/slot B Communication module Ethernet IP/Modbus TCP/MD-Link slot A Complementary Output voltage Permissible temporary current boost Motor slip compensation Acceleration and deceleration ramps Braking to standstill Protection type Frequency resolution Electrical connection Type of connector Physical interface Transmission frame Transmission rate Exchange mode = power supply voltage 1.1 x In 60 s normal duty 1.5 x In 60 s heavy duty Can be suppressed Automatic whatever the load Adjustable Not available in permanent magnet motor law S, U or customized Linear adjustable separately from 0.01 to 9000 s By DC injection Safe torque off motor Motor phase break motor Safe torque off drive Overheating drive Short-circuit protection drive Motor phase break drive Overspeed drive Break on the control circuit drive Overvoltages on the DC bus drive Overload of output voltage drive Line supply overvoltage drive Line supply phase loss drive Line supply undervoltage drive Overcurrent between output phases and earth drive Thermal protection motor Thermal protection drive Display unit Analog input Removable screw terminals mm² AWG 20...AWG 16 control Screw terminal mm² AWG 12...AWG 10 motor Screw terminal mm² AWG 14...AWG 10 line side RJ45 Ethernet/Modbus TCP on the remote graphic terminal RJ45 Modbus serial on the remote graphic terminal 2-wire RS 485 Modbus serial RTU Modbus serial 10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP 2 Data format Type of polarization Number of addresses Method of access Supply Local signalling Width Height Depth Product weight Analogue input number 3 Analogue input type Discrete input number 8 Discrete input type Input compatibility Discrete input logic Analogue output number 2 Analogue output type Sampling duration Accuracy Linearity error Relay output number 3 Relay output type Refresh time Minimum switching current Maximum switching current Isolation Specific application IP degree of protection Variable speed drive application selection 8 bits, configurable odd, even or no parity Modbus serial No impedance Modbus serial Modbus serial Slave Modbus TCP Internal supply for reference potentiometer (1 to 10 kohm) 10.5 V DC +/- 5 % = 10 ma overload and short-circuit protection External supply for digital inputs 24 V DC V = 1.25 ma overload and short-circuit protection Internal supply for digital inputs and STO 24 V DC V = 200 ma overload and short-circuit protection 3 LEDs local diagnostic 3 LEDs dual colour embedded communication status 4 LEDs dual colour communication module status 1 LED red presence of voltage 144 mm 350 mm 203 mm 4.7 kg Software-configurable voltage AI1, AI2, AI V DC 30 kohm 12 bits Software-configurable current AI1, AI2, AI ma 250 Ohm 12 bits Programmable DI1...DI6 24 V DC 3.5 kohm Programmable as pulse input DI5, DI khz 24 V DC Safe torque off STOA, STOB 24 V DC 2.2 kohm Level 1 PLC EN/IEC DI1...DI6 discrete input Level 1 PLC IEC 65A-68 DI5, DI6 discrete input Level 1 PLC EN/IEC STOA, STOB discrete input Positive logic (source) DI1...DI6 5 V 11 V Negative logic (sink) DI1...DI6 16 V 10 V Positive logic (source) DI5, DI6 0.6 V 2.5 V Positive logic (source) STOA, STOB 5 V 11 V Software-configurable voltage AO1, AO V DC 470 Ohm 10 bits Software-configurable current AO1, AO ma 10 bits 2 ms +/- 0.5 ms DI1...DI4 discrete input 5 ms +/- 1 ms DI5, DI6 discrete input 5 ms +/- 0.1 ms AI1, AI2, AI3 analog input 10 ms +/- 1 ms AO1 analog output +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 C analog input +/- 1 % AO1, AO2 for a temperature variation 60 C analog output +/ % of maximum value analog input AI1, AI2, AI3 +/- 0.2 % analog output AO1, AO2 Configurable relay logic R1 fault relay NO/NC cycles Configurable relay logic R2 sequence relay NO cycles Configurable relay logic R3 sequence relay NO cycles 5 ms +/- 0.5 ms R1, R2, R3 relay output 5 ma 24 V DC R1, R2, R3 relay output 3 A 250 V AC resistive 1 R1, R2, R3 relay output 3 A 30 V DC resistive 1 R1, R2, R3 relay output 2 A 250 V AC inductive ms R1, R2, R3 relay output 2 A 30 V DC inductive ms R1, R2, R3 relay output Between power and control terminals Utility IP21 Building - HVAC compressor Building - HVAC compressor centrifugal Food and beverage processing other application Mining mineral and metal fan Mining mineral and metal pump Oil and gas compressor Oil and gas fan Oil and gas pump 3 Motor power range AC-3 Motor starter type Others compressor Water and waste water other application kw V 3 phases kw V 3 phases Variable speed drive Environment Insulation resistance Noise level Power dissipation in W Volume of cooling air Operating position 1 mohm 500 V DC for 1 minute to earth 54.5 db 86/188/EEC 36 W natural convection 380 V 4 khz 145 W forced convection 380 V 4 khz 38 m3/h Vertical +/- 10 degree THDI = 48 % full load IEC Electromagnetic compatibility Conducted radio-frequency immunity test level 3 IEC /50 µs - 8/20 µs surge immunity test level 3 IEC Electrical fast transient/burst immunity test level 4 IEC Electrostatic discharge immunity test level 3 IEC Radiated radio-frequency electromagnetic field immunity test level 3 IEC Pollution degree 2 EN/IEC Vibration resistance 1.5 mm peak to peak Hz IEC gn Hz IEC Shock resistance 15 gn 11 ms IEC Relative humidity % without condensation IEC Ambient air temperature for operation Ambient air temperature for storage C Operating altitude C without derating C with derating factor m with current derating 1 % per 100 m = 1000 m without derating Environmental characteristic Chemical pollution resistance class 3C3 EN/IEC Dust pollution resistance class 3S3 EN/IEC Standards EN/IEC EN/IEC environment 1 category C2 EN/IEC environment 2 category C3 UL 508C EN/IEC IEC IEC IEC IEC Product certifications Marking REACH DNV-GL CSA UL TÜV ATEX zone 2/22 ATEX INERIS CE Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Green Premium product Compliant - since Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference contains SVHC above the threshold - Go to CaP for more details Go to CaP for more details Available Product environmental Available End of life manual 4 Dimensions Drawings Dimensions Views: Right - Front Drives Without IP21 Top Cover Views: Left - Rear 5 Drives Without IP21 Top Cover Views: Left - Rear 6 Mounting and Clearance Clearances X1 X2 X3 100 mm (3.94 in.) 100 mm (3.94 in.) 10 mm (0.39 in.) 7 Mounting and Clearance Mounting Types Mounting Type A: Individual IP21 a 100 mm (3.94 in.) Mounting Type B: Side by Side IP20 Mounting Type C: Individual IP20 a 0 8 Connections and Schema Single or Three-Phase Power Supply with Upstream Breaking via Line Contactor Connection diagrams conforming to standards EN category 1 and IEC/EN capacity SIL1, stopping category 0 in accordance with standard IEC/EN (1) Use digital output R1 set to operating state Fault to switch Off the product once an error is detected. A1 : Drive KM1 :Line Contactor Q2, Q3 Circuit : breakers S1, S2 Pushbuttons : T1 : Transformer for control part 9 Connections and Schema Single or Three-Phase Power Supply with Downstream Breaking via Switch Disconnector Connection diagrams conforming to standards EN category 1 and IEC/EN capacity SIL1, stopping category 0 in accordance with standard IEC/EN 6 (1) Use digital output R1 set to operating state Fault to switch Off the product once an error is detected. A1 : Drive Q1 : Switch disconnector 10 Connections and Schema Control Block Wiring Diagram (1) Safe Torque Off (2) Analog Output (3) Digital Input (4) Reference potentiometer (5) Analog Input A1 : ATV6.. Drive R1A, R1B, Fault R1C relay: R2A, R2C Sequence : relay R3A, R3C Sequence : relay Sensor Connection It is possible to connect either 1 or 3 sensors on terminals AI2 or AI3. 11 Connections and Schema Sink / Source Switch Configuration The switch is used to adapt the operation of the logic inputs to the technology of the programmable controller outputs. Set the switch to Source (factory setting) if using PLC outputs with PNP transistors. Set the switch to Ext if using PLC outputs with NPN transistors. Switch Set to SRC (Source) Position Using the Output Power Supply for the Digital Inputs Switch Set to SRC (Source) Position and Use of an External Power Supply for the DIs Switch Set to SK (Sink) Position Using the Output Power Supply for the Digital Inputs Switch Set to EXT Position Using an External Power Supply for the DIs 12 Performance Curves Derating Curves 40 C (104 F) - Mounting type A, B and C 50 C (122 F) - Mounting type A, B and C 60 C (140 F) - Mounting type B and C In : Nominal Drive Current SF : Switching Frequency 13
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks
SAVE OUR EARTH

We need your sign to support Project to invent "SMART AND CONTROLLABLE REFLECTIVE BALLOONS" to cover the Sun and Save Our Earth.

More details...

Sign Now!

We are very appreciated for your Prompt Action!

x