24LS and 24LC Series - Emergi-Lite

Please download to get full document.

View again

of 2
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Information Report
Category:

Electrical Engineering

Published:

Views: 16 | Pages: 2

Extension: PDF | Download: 0

Share
Related documents
Description
TYPE: CATALOG #: NOTES: COMMERCIAL 24 LS & 24 LC Series 24 Volt Steel Enclosure Features Suggested Specification ã Each unit comes with two (2) EF-18 heads…
Transcript
TYPE: CATALOG #: NOTES: COMMERCIAL 24 LS & 24 LC Series 24 Volt Steel Enclosure Features Suggested Specification ã Each unit comes with two (2) EF-18 heads with 9 watt high intensity Supply and install Emergi-Lite® Series 24 LSC______ 24 LSE______, incandescent lamps (standard) 24 LC______ or 24 LSM______ in 24volt, double heads, with electrically ã All-steel construction with an off-white baked enamel finish compatible remote. exit signs as indicated on the plans. The emergency ã Available with sealed, maintenance-free Nickel-Cadmium, Lead-Calcium lighting unit shall be an architecturally designed, self-contained fixture (Immobilized Electrolyte), or Lead-Calcium batteries including sealed, maintenancefree battery. ã PulsePlus Charger circuitry offers 120/277VAC, input 60 Hz., 0.3/0.15A (other inputs available), fused output circuit(s), dual diagnostic indicator lights, TYPE 24LSC to be supplied with long life Nickel-Cadmium battery. temperature compensation, sealed relay, low voltage battery disconnect, TYPE 24LSE to be supplied with long life pure lead battery. brownout protection and lock out (automatic battery connect) ã Removable front panel TYPE 24LSM to be supplied with Lead-Calcium battery. ã UL924 Listed TYPE 24LC to be supplied with Lead-Calcium (free electrolyte) battery. ã 3-year limited warranty Detailed warranty terms located at: www.emergi-lite.com/usa/files/EL_Warranty.pdf The unit shall supply the rated load for a minimum of 1-1/2 hour s or to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, Accessories (order as a separate item) 60 Hz and be UL924 listed. The unit charger shall utilize a solid-state circuit which samples the battery in relation to its temperature, state DESCRIPTION SUFFIX of charge and input voltage fluctuations. The charger shall be current Mounting bracket (cabinet B) B2 limited, temperature compensated, short-circuit protected and reverse Mounting shelves (cabinet B) MP3-EG polarity protected. The unit shall be furnished with an electronic lockout Mounting shelves (cabinet C) MP6-EG circuit which will connect the battery when the AC circuit is activated Mounting shelves (cabinet D) MP12 and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery Wire Guard (cabinet A) WG2-E disconnect circuit shall be provided and will disconnect the load and Wire Guard (cabinet B & C) WG3-E circuitry from the battery when it reaches 87-1/2% of its nominal voltage. Wire Guard (cabinet D) WG4-E The unit shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with a sealed dust-tight relay, Unit Data a test switch and dual diagnostic LED indicator lights (hi-charge and AC Housing: Heavy duty code gauge steel construction, off-white baked pilot). The cabinet shall be constructed of ____*gauge steel in offwhite enamel cabinet with a removable front panel for ease of install ation enamel color. A removable front panel shall be furnished to provide and servicing. full access for ease of installation and servicing. B cabinet units shall have a universal mounting cluster. All cabinets shall be furnished with B cabinet has a universal mounting cluster. All cabinets are furnished 7/8” conduit knockouts, rear keyhole mounting slots (bracket or shelf with 7/8” conduit knockouts, rear keyhole mounting slots, and provisions available as an option) and pr ovisions for mounting up to 3 heads on for mounting up to 3 heads on cabinet. Light Source: two EF18 heads cabinet. Unit will be furnished with two EF18 lighting heads constructed furnished standard with 9 watt lamps Self-testin g in accordance with of impact resistant, flame retardant thermoplastic material complete NFPA 101, Life Safety Code. Unit tests itself every thirty days for one with 9 watt lamps. Fused output terminals shall be provided for ease minute, thirty minutes on the sixth month and ninety minutes annually. of remote lamp connections . Every 24 LS & 24 LC Series unit shall complete three full cycles of d ischarge and recharge before shipment Electrical and will be certified that this tes ting has been done. Every 24 LS & 24 Power Requirements: 120/277VAC, 60 Hz., 0.3/0.15 Amp (other LC Series unit shall be fully warranted for three years, subject to proper inputs available). Output: 24 Vdc, 2 fused output circuits. Transfer: installation and maintenance. dust-tight sealed relay automatically and instantly energizes lamp The unit shall be Emergi-Lite® model: . load upon failure of A.C. supply. LVD: low voltage battery disconnect circuit automatically shuts down lamp load and circuitr y when battery reaches 87-1/2% of its nominal voltage, preventing deep discharge and permanent damage to the battery. Lockout: labor saving electronic circuit automatically connects battery when A.C. circuit is activated. Brownout: close tolerance electronic circuit activates emergency unit when utility power dips below 80-85% of nominal voltage. Charger: The Pulse-Plus charging circuit utilizes a microprocessor which samples the battery in relation to its temperature, state of charge and input voltage fluctuations. The charger is current limited, temperature compensated, short-circuit protected and reverse polarity protected. The equipment is capable of full recharge in compliance with UL 924 specifications. Transformer: 120/277VAC. Controls: test switch, dual diagnostic LED indicator lights (hi-charging, AC pilot). 33 COMMERCIAL Dimensions Dimensions are approximate and subject to change. Unit Warranty* Entire unit (excluding lamps and fuses) carries a 3-year Full Warranty. For complete warranty information,see Data Sheet ELW. Battery Warranty* Unit batteries are warranted as follows: Sealed Nickel Cadmium: 12LSC – 10year life expectancy, 5-year Full Warranty, plus 5-year pro rata warranty. Sealed Long Life Lead: 12LSE – 12-year life expectancy, 5-year Full Warranty, plus 5-year pro rata warranty. Sealed Lead Calcium: 12LSM – 8-year life expectancy, 3-year Full Warranty, plus 3-year pro rata warranty. Sealed Lead Calcium (Immobilized Electrolyte): 24LC – 12- year life expectancy. 5-year full warranty, plus 5-year pro rata warranty. Cabinet Dimensions *Subject to proper installation and maintenance Size a b c d B 16-3/8” 16-1/8” 5-7/16” 10-1/4” C 18-3/8” 16-1/2” 7-1/4” 12-1/4” D 18-3/8” 27” 7-/4” 12-1/4” Unit Rating Furnished standard with two 9 watt High Intensity Incandescent lamps. Watts to 87-1/2% of rated battery voltage* Sealed Maintenance-Free Battery Types D.C. Voltage Model Number # of Load Fuses Cabinet size 1-1/2 hrs 2 hrs 3 hrs 4 hrs 24 24LSC72-2 72 42 24 12 2 B Nickel-Cadmium 24 24LSC100-2 100 73 37 20 2 B 24 24LC300-2 300 240 132 72 2 D Lead-Calcium 24 24LC350-2 350 280 168 96 2 D (Immobilized Electrolyte) 24 24LC400-2 400 336 192 96 2 D 24 24LSM110-2 110 72 40 24 2 B Lead-Calcium 24 24LSM220-2 220 144 80 48 2 C *National Electrical Code Specification. How to Order COLOR SERIES/CAPACITY # OF LAMPS HEAD STYLE LAMP TYPE OPTIONS Blank= Off white LSC Series -0= No heads Blank= EF18 I_= Incandescent DC-bayonet Blank= No options B= Black 24LSC100= 24V-100W Ni-Cd -1= 1 head (PAR 36 plastic) Z_= Incandescent wedge -AD= Advanced diagnostics* enclosure LSM Series -2= 2 heads 9= EF9 mini plastic M_= Halogen MR16* -ADNA= Diagnostics non-audible* 24LSM110= 24V-110W Lead-Calcium -3= 3 heads 10= EF10 mini H_= Halogen Bi-Pin -NEX= Nexus® wired 24LSM220= 24V-220W Lead-Calcium plastic MR16 L_= MR16 LED -NEXRF= Nexus® wireless 32= EF32 cylinder -V= Voltmeter (A cabinet units. LC Series 24LC300= 24V-300W Lead-Calcium lamp heads Choose A or V only) 24LC350= 24V-350W Lead-Calcium 150= EF150 MR16 -A= Ammeter* 24LC400= 24V-400W Lead-Calcium lamp heads -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -CP= Cord and plug 120V** -E= Cord and plug 277V * Available with EF10 & 150 only * Minimum lamp load required: NOTE: For a complete list of available lamp 20% of unit capacity. Not available types, please refer to the lamp data on with 24V-100W Ni-Cd p. 140-141 ** Standard cord is 3 ft. Example: 24LSC100-2150MH All information and specifications contained in this specsheet are subject to change due to engineer design, errors and omissions. Illustrations and diagrams within this specsheet may vary from actual products. 35 2016© Thomas & Betts Limited. All rights reserved.
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks